Electrical specifications
|
Current measurement dc and ac 10 Hz to 100 Hz |
Range : 40 A |
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A |
Range : 400 A |
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A |
Range : 2000 A; 1400 ac rms |
Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A |
|
Crest Factor (50/60 Hz) |
Range : 40 A |
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A |
Range : 400 A |
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A |
Range : 2000 A; 1400 ac rms |
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A |
|
Current measurement ac 100.1 Hz to 1 kHz |
Range : 40 A |
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A |
Range : 400 A |
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A |
Range : 2000 A; 1400 ac rms |
Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A |
|
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) |
Range : 4 V |
Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V |
Range : 40 V |
Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V |
Range : 400 V |
Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
Range : 600 V ac rms |
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
Range : 1000 V dc |
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits |
|
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) |
Range: 4 V |
Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V |
Range: 40 V |
Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V |
Range: 400 V |
Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
Range: 600 V ac rms |
Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
|
Ohms measurement (355 only) |
Range: 400 Ω |
Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits |
Range: 4 kΩ |
Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits |
Range: 40 kΩ |
Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits |
Range: 400 kΩ |
Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits |
|
Continuity beeper (355 only) |
|
On at ≤ 30 Ω |
|
Off at ≥ 100 Ω |
|
Frequency measurement |
Measurement range |
5.0 Hz to 1 kHz |
Resolution |
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
Accuracy – 5.0 Hz to 100 Hz |
0.2 % + 2 counts |
Accuracy – 100.1 Hz to 1 kHz |
0.5 % + 5 counts |
Trigger level |
Refer to current and voltage tables |
|