DC/AC Clamp Meter
CE CAT III 600V, CAT IV 300V
Features:
1. High resolution DC/AC 10 mA current measurement (<60A range).
2. DC/AC current measurement: 60/400A.
3. DC/AC voltage measurement: 60/600V.
4. AC current measurement: TRMS (model A1).
5. AC current measurement: Average Sensing (model A3).
6. Resistance, Continuity, Capacitance and Temperature (℃/℉) measurement.
7. Non-contact (A) and Contact (V) Frequency measurement.
8. Voltage/Current Peak value measurement.
9. Auto range: V, A, Resistance, Capacitance and Temperature.
10. One Touch Zero for DCA adjustment.
11. 25mm large jaw diameter.
12. Auto-power-off function (30 min.).
13. With backlight.
14. Max Hold, Peak Hold and Delta ( ) functions.
15. Dual display: Hold + Average, Max + Min, Max + Min.
16. Dual display: Peak Max + Peak Min, Peak Max + Peak Min.
17. On-line automotive battery and alternator testing Min battery cranking voltage and Max alternator charging voltage.
18. Low Pass Filter (LPF, 1KHz) (for VFD measurement).
19. 600V overload protection for ohm and measurement.
20. Ideal for works in crowded switch box or cable areas.
21. Applications:
(1) Troubleshooting in
i. Automotive Maintenance
ii. electric vehicle
iii. plant maintenance
iv. HVAC
v. telecom works
vi. marine
vii. motorcycle repairs
(2) DC charging current of batteries of electric vehicles.
(3) DC current consumption of DC motors of Drones.
(4) DC current output of solar panels.
(5) Measurements of voltage, current, and frequency of inverters (VFD).
(6) Temperature measurements of abnormal components.
Electrical Specifications: (23℃±5℃)
DC Current
Range Resolution Accuracy Overload
Protection
60 A 10mA ±1.5%±2dgts
DC 400A
0-150 A 100mA ±1.5%±2dgts
150-300 A 100mA ±2.2%±2dgts
300-400 A 100mA ±4%±2dgts
DCA Peak MAX ±400A Accuracy + (±2%±50dgts)
AC Current (A1: True RMS, A3: Average Sensing)
Range Resolution Accuracy Overload
Protection
50/60 Hz 40 - 500Hz
60A 10mA ±1.5%±3dgts ±2.0%±4dgts
0-150A 100mA ±1.5%±3dgts ±2.0%±4dgts AC 400A
150-300A 100mA ±2.2%±3dgts ±2.5%±4dgts
300-400A 100mA 4%±3dgts 5%±4dgts
ACA Peak MAX ±400A Accuracy + (2%±50dgts)
LPF @1KHz -3db
DC Voltage (Overload Protection 600V)
Range Resolution Accuracy Input Impedance
60V 10 mV ±1.5%±3dgts 10MΩ
600V 100 mV
DCV Peak MAX ±600V Accuracy + (±2%±50dgts)
AC Voltage (A1: True RMS, A3: Average Sensing) (Input Impedance 10 MΩ)
Range Resolution Accuracy Overload
Protection
50/60 Hz 40 - 1KHz
60V 10mV ±1.5%±5dgts ±2.0%±5dgts AC 600V
600V 100mV
ACV Peak MAX ±850V Accuracy + (±2%±50dgts)
LPF @1KHz -3db
Continuity (Open voltage 0.4V, Overload protection AC 600V)
Range Resolution Accuracy Beeping
60-600Ω 0.1Ω ±1.0%±2dgts <30.0Ω (approx.)
Resistance (Ω) (Open voltage 0.4V)
Range Resolution Accuracy Overload
Protection
600Ω 0.1Ω
±1.5%±2dgts AC 600V
6KΩ 1Ω
60KΩ 10Ω
600KΩ 100Ω
Frequency (auto range)
Resolution Sensi- Overload
Range (Hz) Accuracy
(Hz) tivity Protection
4-99.99 0.01 ±0.5%±0.02 V:3V/10V
A:1A/5A
100.0~999.9 0.1 ±0.5%±0.2 V:2V/10V
A:1A/5A
AC 600V
1.000K-9.999K 10 ±0.5%±20 V:2V/10V
A:1A/5A
AC400A
V:2V/10V
10.00K-99.99K 1.2K ±0.5%±2.4K
A:1A/5A
V:2V/10V
100.0K-200.0K 5K ±0.5%±10K
A:1A/5A
Temperature (for using K-Type thermocouples, ℃ or ℉)
Range Resolution Accuracy Overload
Protection
-40 – 0 ℃ 0.1 ℃ ±2.0%±2 ℃
AC 300V
0 – 400 ℃ 0.1 ℃ ±0.5%±2 ℃
-40 – 32 ℉ 0.1 ℉ ±2%±3.6 ℉
32 – 752 ℉ 0.1 ℉ ±0.5%±3.6℉
Diode Test
Range Resolution Accuracy Overload
Protection
0 – 1.999V 0.001V ±2.5%±5dgts AC 600V
Capacitance
Range Resolution Accuracy Overload
Protection
600nF 0.1nF ±2.0%±0.2 nF
6μF 1nF ±2.0%±0.02μF
AC 600V
60μF 10nF ±2.0%±0.02μF
600μF 100nF ±2.0%±0.2μF
6000μF 1μF ±2.5%±5μF
General Specifications: Indoor Use
Conductor Size: 25mm max. (approx.)
Battery Type: two 1.5V SUM-3
Display: 6000 counts
Range Selection: Auto and Manual
Overload Indication: OL
Power Consumption: 17 mA (approx.)
Low battery Indication:
Sampling Time: 2 times/sec.
Auto-power-off: 30 minutes
Operating Temperature: 0 C to 50 C
Operating Humidity: less than 85% relative
Altitude: up to 2000M
Storage Temperature: -20 C to 60 C
Storage Humidity: less than 75% relative
Dimension: 190mm (L) x 66mm (W) x 36mm (H)
7.5" (L) x 2.6" (W) x 1.45" (H)
Weight: 250g (battery included)
Accessories: Carrying bag x 1
Users manual x 1
1.5V battery x 2
Test leads x 1
K-type thermocouples x 1
Adapter (for Capacitance and K-type thermocouples) x 1